Data Category sas_scan_intensity

General

Category name
sas_scan_intensity
Required in PDB entries
no
Category group membership
intensity_group  sas_group
Used in current PDB entries
No

Category Relationship Diagrams

70
View full category relationship diagram including all dictionary data categories

Category Description

          This category gives the measured and processed intensities
          and the corresponding momentum transfers.

Category Example

     loop_
     _sas_scan_intensity.id
     _sas_scan_intensity.scan_id
     _sas_scan_intensity.momentum transfer
     _sas_scan_intensity.intensity
     _sas_scan_intensity.intensity_su_counting
     _sas_scan_intensity.intensity_su_systematic
     _sas_scan_intensity.exposure_time
     _sas_scan_intensity.resolution_width
##
## IDB: in this example I am not sure what is a reasonable value for the resolution
## width.
# The following is the scan from the sample
1  1  0.1  1258   35  20   15 ?
2  1  0.2   953   30  20   15 ?
3  1  0.3   876   30  20   15 ?
4  1  0.4  1467   34  20   20 ?
........
# The following is the scan from the matrix
53 2  0.1   350   15  20   15 ?
54 2  0.2   325   15  20   15 ?
........
# The following is the scan of the background
104 3 0.1    24    3  20   15 ?
105 3 0.2    35    4  20   15 ?
........

Key Data Items