Residual factor Rcullis,acen for acentric reflections for this
derivative.
The Cullis R factor was originally defined only for centric
reflections. It is, however, also a useful statistical
measure for acentric reflections, which is how it is used in
this data item.
sum| |Fphobs +/- Fpobs| - Fhcalc |
Rcullis,acen = ----------------------------------------
sum|Fphobs - Fpobs|
Fpobs = the observed structure-factor amplitude of the native
Fphobs = the observed structure-factor amplitude of the
derivative
Fhcalc = the calculated structure-factor amplitude from the
heavy-atom model
sum is taken over the specified reflections
Ref: Cullis, A. F., Muirhead, H., Perutz, M. F., Rossmann, M. G.
& North, A. C. T. (1961). Proc. R. Soc. London Ser. A,
265, 15-38.